دوره 3، شماره 1 - ( 2-1398 )                   جلد 3 شماره 1 صفحات 5-1 | برگشت به فهرست نسخه ها


XML English Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Pourshakibaei P, Mashkouri Najafi M T, Akbari Zahmati A H, Afiat M, Vaghari M. Comparison of Accuracy of Self-Developing Films and Conventional Films for Radiographic Determination of Distance between File Tip and Radiographic Apex in Root Canal Therapy. jcbr 2019; 3 (1) :1-5
URL: http://jcbr.goums.ac.ir/article-1-189-fa.html
پورشکیبایی پریچهر، مشکوری نجفی محمد تقی، اکبری زحمتی امیرحسین، عافیت مهرنوش. Comparison of Accuracy of Self-Developing Films and Conventional Films for Radiographic Determination of Distance between File Tip and Radiographic Apex in Root Canal Therapy. Journal of Clinical and Basic Research. 1398; 3 (1) :1-5

URL: http://jcbr.goums.ac.ir/article-1-189-fa.html


چکیده:   (3672 مشاهده)
Background and objectives: The developing process is necessary for converting a latent image into a visible image in conventional dental x-ray films. Despite the considerable advances made in development of radiographic equipment, there are also still some unresolved issues in this field. New self-developing film is an alternative to manual processing. The purpose of this study was to compare accuracy of self-developing films and conventional films (E-speed) for determination of the distance between file tip and radiographic apex in root canal therapy in laboratory conditions.
Methods: This study was done on 25 single-canal, single-rooted premolar teeth. After obtaining tooth length, each tooth was accessed and K-files No. 15 and 25 were placed inside the canal tip to tip with the tooth apex. Then, 1mm of the actual tooth length was reduced and periapical radiographs were captured using self-developing films and conventional films (E-speed) under standard conditions. Two endodontists observed the films twice at different intervals. The obtained data were analyzed with SPSS software (version 18) using paired t-test.
Results: Average distance between the tip of file No.15 to the radiographic apex in conventional film and self-developing film was 0.37 mm and 0.35 mm, respectively. The mean working length measured using K-file No. 25 was 0.44 mm in conventional film and 0.40 mm in self-developing film. There was no statistically significant difference between the two methods for measuring the working length.
Conclusion: The self-developing films provide a radiographic image that is diagnostically equivalent to the conventional film for measurement of the distance from the file tip to the radiographic apex in single-rooted teeth with a single canal.
متن کامل [PDF 422 kb]   (1619 دریافت)    
نوع مقاله: پژوهشي |

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به Journal of Clinical and Basic Research می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2024 CC BY-NC 4.0 | Journal of Clinical and Basic Research

Designed & Developed by : Yektaweb

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0).